The following information applies to combined heating and cooling ducts in zone 4 areas.
													
																	Duct insulation r value requirements. 
								
	
		
	
																	You can follow him on twitter at energyvanguard. 
																	Existing 3 4 inches of insulation. 
																	Or component performance alternative of section c402 1 5 roof solar reflectance and thermal emittance fenestration in building envelope. 
																	R value of r 6 is required for exterior ductwork or ducts installed in a ventilated attic or an unvented attic above a. 
															
													
								
	
		
	
																	For example if you have a type of insulation that has an r value of r 5 per inch of thickness you will need a depth of 6 inches of this insulation installed your attic to reach r 30 if you live in zones 2 or 3. 
																	If the lesser r value most likely the duct r value is chosen the envelope of the building must be shown to comply with a performance based option. 
																	R value based method of section c402 1 3 u c and f factor based method of section c402 1 4. 
																	Insulation r value to match the supply duct. 
															
													
								
	
		
	
																	And that means it s time to deal with duct insulation in a more meaningful way than just increasing the required r value to 8 for ducts in attics. 
																	The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. 
																	Insulation r value must meet either the requirement for above grade walls or for exterior ducts. 
																	Recommended insulation levels for retrofitting existing wood framed buildings. 
															
													
								
	
		
	
																	R value of 3 5 is required for buried ductwork and ducts installed in an unvented attic. 
																	Ashrae 90 1 also has a requirement of r 1 9 for supply ducts installed in indirectly conditioned spaces which includes plenum spaces above ceilings. 
																	Ashrae 90 1and the ieccboth require r 6 insulation for ducts in unconditioned spaces and r 8 or r 12 depending on the climate zone for ducts installed outside the building. 
																	Specific insulation requirements of section c402 2 thermal requirements of either. 
															
													
								
	
		
	
																	The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.